the code is:
BEEF02060062E44B0100000000
5. Get "COLOR TEMPERATURE" Value for the Current Source
Send the packet:
BEEF0319009D0B02C20900000000000000000000000000000000000000000000
The unit returns the code:
1EBEEF031900C41F02C2090100000000000D000000000000000000000000000000
where bytes Number 17 and Number 18 (underlined above) carry the requested value. The returned
value is 0D which corresponds to point 14 in the OSD Color Temperature chart.
6. Warnings
When the number of bytes sent to the Projector is greater than indicated for the Command (32 bytes for
Operation Packets and 13 bytes for Event Packets), excess data will be ignored.
Conversely, if number of bytes sent to the Projector is smaller than required by the Communication Protocol,
the command may be ignored.
Command execution time may vary from few milliseconds to 500 milliseconds, depending on the operation
that have been requested.
If the unit is busy when a command is sent, the unit may not accept the command. If several commands are
to be sent one after the other, sufficient time between them should be allowed.