Sierra Monitor Corporation ZSE30 Switch User Manual


 
ZSE30 ISE30
Rated Pressure Range
-
100 to 100 kPa 0 to 1 MPa
Set Pressure Range
-
101 to 101 kPa
-
0.1 to 1 MPa
Withstand Pressure 500 kPa 1.5 MPa
Setting and Display Resolution
0.2 kPa 0.001 MPa
Fluids Air, inert gases and incombustible gases
Power Supply Voltage
12 to 24V DC, ±10%,ripple (p
-
p) 10% or less(Protected against inverse connection)
Current Consumption 45mA or less (No load)
Switch Output Note 1) NPN or PNP open collector output .1 output
Max. Load Current 80mA
Max. Impressed Voltage
30V (During NPN output)
Residual voltage 1V or less (@80mA load current)
Response Time
2.5ms
or less
(chattering
-proof function working :20,160,640 or 1280ms selectable)
Short Circuit Protection
Provided
Repeatability
±0.2%F.S. ±2 digits or less ±0.2%F.S.±1 digit or less
Voltage Output
Note 2)
Output Voltage : 1 to 5V ±2.5%F.S. or less (within rated pressure range)
Linearity : ±1%F.S. or less, Output impedance : Approx. 1k
A
nalog
Output
Current Output
Note 3)
Output Current : 4 to 20mA ±2.5%F.S. or less (within rated pressure range)
Linearity : ±1%F.S. or less
Max. Load Impedance : 300 (@12VDC), 600 (@24VDC) Min. Load Impedance : 50
Hysteresis Mode
Hyster
esis
Window Comparator
Mode
Variable(from 0)
Display Method 3.5 digits 7-segment display, dual-color display(red/green) Sampling rate:5 times/1 sec
Indicator Accuracy
±2%F.S. ±2 digits (@25±3°C) ±2%F.S. ±1 digit (@25±3°C)
Indicator Lamp Lit when ON (Green)
Temperature Characteristic
±2%F.S. or less (@25°C reference)
Enclosure IP40
Ambient Temperature
O
p
eration : 0 to 50°C, Stora
g
e :
-
10 to 60°C
(
No condensation or no freezin
g)
Ambient Humidity
O
p
erationStora
g
e : 35 to 85%RH
(
No condensation
)
Withstand Voltage 1000VAC,1 minute (between lead block and case)
Insulation Resistance
50M or more
@
500VDC M
(
between lead block and case
)
Vibration proof
10 to 150 Hz, 1.5mm double amplitude, 2 hours each in directions of X, Y and Z respectively
Impact proof 100m/s
2
, 3 times each in directions of X, Y and Z respectively
Standard
CE marking, UL/CSA(E216656)
Note 1) Analog output cannot be selected when switch output is selected.
Note 2) Both switch output and current output cannot be selected simultaneously when voltage output is
selected.
Note 3) Both switch output and voltage output cannot be selected simultaneously when current output is
selected.
Piping specification
Model 01 T1 C4H C6H N7H C4L C6L N7L
Port size
R1/8
M5×0.8
NPT1/8
M5×0.8
One-touch fitting
straight type
φ4mm
φ5/32inch
φ6mm φ1/4inch
One-touch fitting
elbow type
φ4mm
φ5/32inch
φ6mm φ1/4inch
Sensor pressure sensing part: silicone, Pipe port: C3602 (electroless nickel plating),
Material
O-ring: HNBR
O-ring: NBR O-ring: NBR, Fitting: PBT
Lead wires with
connector included
(2m)
81g 76g 78g
Mass
(Weight)
Lead wires with
connector not included
43g 38g 40g
Environment
-8-
PS##-OMF0010-C
Specification