7-3
ROUTING SWITCHER SYSTEM (E)
SOURCE/DEST/PHANTOM TYPE DVS-128 V1.00 STATION NUMBER 1
TYPE:32
0=IN 1=OUT 2=.... 3=.... 4=.... 5=.... 6=.... 7=....
8=.... 9=.... A=.... B=.... C=.... D=.... E=.... F=....
G=.... H=.... I=.... J=.... K=.... L=.... M=.... N=....
O=.... P=.... Q=.... R=.... S=.... T=.... U=.... V=....
F1:TYPE Ctrl-E:RETURN TO MENU
7-2. Changed Menu (Primary Station Setting Items)
A : DISPLAY CONTROL AREA
(DVS-128/HDS-X3000 Series)
Purpose
This menu displays the control size as the primary station.
Example of Display Screen
When LEVEL: 1 to 16 on the [E: SET LEVEL TABLE]
screen is set to 1, the message [SOURCE No. 0001-1024
DESTINATION No. 0001-0512 LEVEL 1-16] appears.
There are no input items or set items on this screen.
B : SET SOURCE/DEST TYPE
(DVS-128/HDS-X3000 Series)
Purpose
This menu is used to set the type name of the source
destination and global phantom table.
The menu makes the management of source/destination
easier.
The alphanumeric characters of 4 characters or less can be
used. Either 16 type data or the 32 type data can be
selected for the terminal numbers of 1 to 512.
Example of Setting Screen
. Every pressing of [F1:TYPE] triggers between TYPE:
16 and TYPE: 32. Either one of the data structures of
the terminal name to be handed by the S-P1, is selected.
. When [F1] is pressed, the message [Do you change the
type number? Y or N] appears. When either [Y] or [N]
is pressed, change the setting of the type number.
The terminal name from 1 to 512
. TYPE : 16 The names up to 16 types can be used.
When the S-P1 type remote control panel
or the UMD is used in the system, select
the TYPE 16.
. TYPE : 32 The names up to 32 types can be used.
When the S-P1 type remote control panel
or the UMD is used in the system, the
correct display or correct operation
cannot be performed.
The terminal names of No. 513 to 1024 are fixed to type
32 without affected by this setting.
DISPLAY CONTROL AREA DVS-128 V1.00 STATION NUMBER 1
SOURCE No 0001-1024 DESTINATION No 0001-1024 LEVEL 1-8
Ctrl-E:RETURN TO MENU