Sony CPD-100GST Computer Monitor User Manual


 
17
Getting Started
Technical Features
F
EN
ES
C
1
2
3
4
5
Damper Wires
When viewing a white background, very thin horizontal
lines are visible on the screen as shown below. These lines
are damper wires.
The Trinitron tube has a vertically striped aperture grille
inside. The aperture grille allows more light to pass
through to the screen giving the Trinitron CRT more color
and brightness.
These damper wires are attached to the aperture grille to
prevent vibration of the aperture grille and keep the screen
image constantly stable.
Damper wire
Approx. 6cm
(CPD-200GST
only)
Approx. 6cm
Plug & Play
This monitor complies with the DDC1 and DDC2B
Display Data Channel (DDC) standards of VESA.
When a DDC1 host system is connected, the monitor
synchronizes with the V. CLK in accordance with the VESA
standards and outputs the EDID (Extended Display
Identification Data) to the data line.
When a DDC2B host system is connected, the monitor
automatically switches to the appropriate standard.
DDC is a trademark of the Video Electronics Standard
Association.
Displaying the monitor’s
information
You can display the model name, serial number and year of
manufacture using the monitor‘s INFORMATION OSD.
Press and hold the MENU button for 5 seconds.
The INFORMATION OSD appears.
Example:
The INFORMATION OSD includes the model name, serial
number and manufactured year.
The OSD automatically disappears after about 30 seconds.
MENU
INFORMATION
SER NO
:
1234567
MODEL
:
CPD 100GST
MANUFACTURED
: 1997
Power Saving Function
This monitor has three modes of reduced power
consumption. By sensing the absence of video signal
coming from the computer, it reduces power consumption
as follows.
Note
If no video signal is input to the monitor, the “NO INPUT
SIGNAL” message (page 18) appears. After 30 seconds, the power
saving function automatically puts the monitor into the active-off
mode and the u indicator lights up orange. Once the horizontal
and vertical sync signals are detected, the monitor automatically
resumes its normal operation mode.
Recovery
time
Approx.
5 sec.
Approx.
5 sec.
Approx.
5 sec.
u indicator
Green
Green and orange
alternate
Green and orange
alternate
Orange
Off
Power
consumption
mode
Normal
operation
Standby
(1st mode)
Suspend
(2nd mode)
Active-off
(3rd mode)
Power-off
Power
consumption
120 W
(CPD-200GST)
110 W
(CPD-100GST)
15 W
15 W
8 W
0 W