Source Technologies ST9650 Printer User Manual


 
Source Technologies, LLC ST9650 Secure MICR Printer User’s Guide
62
Error Message
on Display
Printed
Message
Description Action
MICR Definition
Line Count Error
The number of digits in
the MICR definition
Command is not equal
to four, or there is a
non-hexadecimal
character in the count.
Check your software for
errors in the MICR
definition Command
(SMCP).
MICR Password
Error
Password
Length Error.
Password length is not
equal to eight
characters.
Check the Password
Command in your
software, it must be eight
characters long.
MICR Password
Error
Password
Match Error
Password sent does
not match the current
stored password.
Check the Password
Command in your
software.
Non-
hexadecimal
Value Received
Non-
hexadecimal
value
received.
A command contained
a non-hexadecimal
value in a parameter.
Check the Command
(&%STL, STY) syntax for
errors.
Non Integer
Value Received
Non integer
value
received.
A parameter in a
command was not an
integer.
Check the command
(&%STL, STS, STP) for
syntax/ numbering errors.
Password Not
Enabled Error
A secure command
was sent without the
password being sent
first
Check the software to
ensure that the password
is sent before any secure
commands.
Purge Audit
Report, Then
Format
An SFF command was
received, but there is
audit data in flash
which should not be
erased
Purge the audit data, then
resend the SFF command
Secure File Not
Unlocked/Opene
d/Written/Read
There was an internal
error while trying to
access Flash for an
STL or STP command
Print the menus to ensure
that Flash is installed.
Print a directory of Flash
to ensure that is it not
write protected or full. If
error occurs on STP
command, check to
confirm that the resource
is stored in Flash.
Error Messages | 9