The following table summarizes the Netra 240 server’s enclosure and power specifications.
Table 2-2: Enclosure and power specifications of the Netra 240 server.
Configuration Netra 240 Server
Dimensions Height: 87.4 mm (3.44 in.) – 2 RU
Width: 425 mm (16.73 in.) without bezel
442 mm (17.4 in.) including bezel
Depth: 483 mm (19 in.) to rear connectors
508 mm (20.0 in.) overall max.
Weight 16.3 kg (36 lbs.)
18.6 kg (41 lbs.) fully configured with rackmount kit
Power 90–264 V AC (47-63 Hz) / -48 V DC or -60 V DC nom (-40 to -75 V DC range)
6.1 amps maximum (at 90 V AC) and 15 amps maximum (DC)
Dual, redundant 400 Watt power supplies
Environmental and Safety Specifications
As summarized in the following table, the Netra 240 server meets all relevant domestic and international agency
safety, ergonomics, EMI, and environmental requirements.
Table 2-3: Environmental and safety specifications of the Netra 240 server.
Specification Operating Nonoperating
Ambient temperature AC: 0° C (32° F) to 40° C (104° F) AC: -40° C (-40° F) to 70° C (158° F)
DC: -5° C (23° F) to 45° C (113° F) DC: -40° C (-40° F) to 70° C (158° F)
Relative humidity AC: 10% to 90% (noncondensing), AC: Up to 93% (noncondensing)
40° C max wet bulb
DC: 5% to 93% (noncondensing) DC: Up to 93% (noncondensing)
Altitude Up to 3000 m Up to 12,000 m
Acoustic noise Operating: 7.0 B —
(ISO 9296) Idling: 7.0 B
ETSI EN 300 019-2-1,2,3, Table 3.1 & 3.1 E
Seismic GR-63-Core requirements for earthquake Zone 4
Safety IEC60950, UL/CSA60950, EN60950
RFI/EMI compatibility FCC Class A, Part 14 47 CFR, EN55022, CISPR 22, EN 300-386:2001 V1.3.1, ICES-003
Immunity EN55024
Certifications
Safety cULus Mark, TUV GS Mark, CE Mark, CCC, GOST R
EMC CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, C-Tick, MIC
Telecommunication Telcordia GR-63 CORE, GR-1089-CORE, SR 3580 NEBS Level 3
Sun Microsystems, Inc.P14 Netra 240 Server Architecture