10 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide May 2007
6. Align the NEM with the chassis guidance system and slide the NEM into its slot
(see
FIGURE 2-2).
Ensure that the NEM engages with the system chassis guidance system. Failure to
align the NEM correctly can result in damage with the internal connection to the
chassis midplane.
FIGURE 2-2 Inserting the NEM Into the Chassis
7. Push the ejector levers toward each other and close the levers to secure the NEM
in its slot.
After you physically install the NEM in its slot, the Chassis Monitoring Module
(CMM) will automatically detect the presence of the NEM. The OK LED goes to
Standby blink (see
TABLE 2-3 for LED status).
8. Press the Attention button to notify the blades (host operating systems) of the
presence of the NEM.