Superior SS2000MD4 Computer Drive User Manual


 
Danaher Motion Superior Electric
SS2000MD4 17 400030-
043 Rev G
4.7.4 Timing Requirements
PULSE
Max. Frequency.......20 kHz
Max. Rise and
Fall Times................1 microsecond
Min. Pulse
Width.......................25 microseconds
Other Signals
Response Time ....... 25 microseconds
4.5 - 6.0 VDC, 16 mA PER SIGNAL
OPTO IN
PULSE
DRIVE
CONTROL SIGNAL
TTL
7406
5V
OPTO IN
PULSE
DRIVE
SWITCH
OPTO 5V GND
OPTO IN
PULSE
DRIVE
560 ohms
1/4 watt
12 VDC, 16 mA PER SIGNAL
CONTROL SIGNAL
CONTROL LOGIC COMMON
4.5 - 6.0 VDC, 16 mA PER SIGNAL
OPTO IN
PULSE
DRIVE
CONTROL SIGNAL
CONTROL LOGIC COMMON
Figure 4.2 Suggested Methods For Control Interface
4.8 INDICATOR LIGHTS
"FAULT" LED, Red
Lights to indicate over current condition. This condition is caused by motor wiring errors or a
ground fault.
Recovery from over current condition requires removing and then reapplying the power.