Symantec ATCA-2210 Switch User Manual


 
Installation Guide
10
3. Enter the exit command again, to log off the SCM.
4. If you have two SCMs installed, repeat these steps on the other SCM.
Verify shelf management operation
These steps confirm that shelf management is operating when the SCM is installed in a RadiSys shelf. If
the SCM is installed in a non-RadiSys shelf, shelf management is not available.
1. Verify that you are at this prompt.
ATCA-2210#
If you are not at the appropriate prompt, see Connect to the SCM on page 6 for instructions on
how to get there.
2. Enter this command to get to the platform management command line interface (CLI).
platform-mgmt
3. Enter this command and verify that the Shelf Manager is started.
shelf-mgmt show all
If
unknown appears instead of Active or Standby for the Status, the Shelf Manager is not
operational. Refer to the troubleshooting section of the Shelf Management Software Reference for
a list of possible solutions.
4. Enter this command to exit the platform management CLI.
exit
5. If you have two SCMs installed, repeat these steps on the other SCM.
Disable the Shelf Manager on the SCM
By default, the SCM is configured to function in a RadiSys shelf. For an SCM to operate in a non-RadiSys
shelf, you must disable the Shelf Manager on the SCM.
1. Connect the included serial port cable by plugging one end into the RJ-45 serial port labeled “LMP
SER” on the SCM.
2. Connect the cable’s other end to the COM1 or the COM2 serial port of an external computer, such
as a laptop.
3. Start a terminal-emulator application, such as Procomm Plus® or minicom, from the operating
system on your computer or laptop. Specify 115,200 baud, 8 data bits, no parity, one stop bit, and
no hardware or software flow control.
4. Press the Enter key and verify you get a login prompt. Enter root at the prompt.
5. The following displays at the prompt of the connected computer:
root@ATCA-2210@ DEBUGMODE :~#
This DEBUGMODE prompt is a result of a conflict between the Shelf Manager on the SCM and the
Shelf Manager on the non-RadiSys shelf. Disabling the Shelf Manager on the SCM resolves this
conflict.