TDK FPS1000-32 Power Supply User Manual


 
40
Notes:
*1: The Output of all the FPS1000 modules are floating in the rack.
*2: For input voltage lower than 100Vac, maximum output power derated by 10% of the power rating.
*3: For cases where conformance to to various safety standards (UL, EN etc.) is required, to be described
as 100-240Vac (50/60Hz).
*4: Remote sensing can compensate up to 1V drop on each load wire.
*5: Not apllicable for units with I
2
C bus option.
*6: Factory default: ON/OFF_1 P.S. is On when AC is applied.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Number of power supply modules (*1)
Maximum output power (*2)
Input voltage / frequency range (*3)
Maximum input current (at 100/200Vac)
AC input connector
Output terminals
Remote sensing (*4)
Parallel operation
Series operation (*5)
Remote On/Off control (*6)
DC_OK signal
AC fail signal
Over Temperature alarm signal
Vout voltage trimming
Auxiliary power supply
Operating temperature
Storage temperature
Operating humidity
Storage humidity
Vibration
Shock
Applicable safety standards
Withstand voltage
Insulation resistance
Weight (Typ)
Size (W*H*D)
Warranty
---
W
---
A
---
---
V
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Kg
---
Yr
Maximum 3 x FPS1000 modules.
3000
85~265Vac continuous, 47~63Hz, Single phase
12.0/6.0 for each FPS1000 unit installed
FPS-T1U :IEC inlet for each power supply module . FPS-T1U/P :None
Bus-bars.Refer to outline drawing.
Possible.
Possible. Up to 3 racks with max 8FPS 1000 units of the same voltage and current rating.
Possible. Up to 3x FPS1000 units of the same voltage and current rating
Separate control for each FPS 1000 unit , By electrical signal or dry contact
On/Off logic is user selectable. Refer to instruction manual.
Separate control for each FPS1000 unit, Open collector signal.
On when Vout >80% +/-5%. Max.sink current: 10mA
Separate control for each FPS1000 unit ,Open collector signal.
Refer to Instruction Manual
Separate control for each FPS1000 unit ,Open collector signal.
Refer to Instruction Manual
Possible, via separate control for each FPS1000 unit .Refer to Instruction Manual.
11.2~12.5VDC.Maximum output current:0.25A, for each FPS1000 unit.
0~50°C: 100% load. Derate 2%/°C, 50°C to 60°C.
-30~85°C
10~90% RH, no condensation.
10~95% RH, no condensation.
Built to meet ETS 300 019
Built to meet ETS 300 019
UL60950-1, EN60950-1
Input-Output: 3000Vrms, 1min. Input-Ground: 2000Vrms, 1min. Output-Ground:
1414Vdc, 1min.
More than 100Mohm at 25°C and 70% RH. Output-Ground: 500Vdc
3.7
440x44x351mm. Refer to Outline Drawing.
Two Years