3-1
3-4. 120-240 VAC CHARGER AND AC TO DC CONVERTER LIMITS
The unit is designed with a single point AC receptacle for external
power to operate both the internal charger and converter. The units
AC voltage range can be factory set from 105 to 250 VAC at 50 to 60
Hz depending upon customer requirements. The AC power cord provided
with the unit is the mechanism that ensures the specified AC power
source is properly supplied to the unit (see paragraph 3-5).Use no
others
INTERNAL CHARGER: NO LIMIT AC power cord can remain connected
when power cells are fully charged. When the power cells are fully
charged the unit’s intelligent charger will go to a stand-by mode,
monitor the power cells state of charge, and only charge the power
cells to ensure they stay at maximum capacity.
INTERNAL AC TO DC CONVERTER: LIMITED (see paragraph 3-6, 3-8 and
3-10). AC power cord does not have to be disconnected when con-
verter power output is no longer required. Once DC power demand
is terminated the unit’s intelligent charger will remain on line to
ensure power cells are charged to maximum capacity.
CAUTION
Unit will be damaged if unapproved AC power is applied.
3-5 AC POWER CORD LIMITS
The AC power cord governs which AC power source the unit is set to
operate from. The Turbo Start 2000 is supplied with a single cus-
tomer specified AC power cord. Some customers may specify a univer-
sal AC option (for worldwide mobility), which comes with two (2)
power cords, one for 120 VAC 60 Hz and the other for 240 VAC 50 Hz
(SEE APPENDIX A). Each power cord is marked accordingly. Below are
the following three (3) types of AC power cords available and their
limits.
120 VAC 60 Hz power cord (USA): LIMITED TO 105-125 VAC 60 Hz power
source only.
120 VAC 60 Hz power cord (Universal): LIMITED TO 105 VAC to 250 VAC
50/60 Hz power source using proper cord set.
240 VAC 50 Hz power cord (European): LIMITED TO 210-250 VAC 50-60 Hz
power source only.
FOR MORE INFORMATION ON POWER CORDS SEE APPENDIX A
*8$5’)520 ,1&255(&7
32:(5 6285&(