Toshiba 510D Server User Manual


 
When using NetWare
(1)
(2)
5.1
Follow the installation procedure described in the
instruction manual to ensure that the installation is
done properly.
About expansion of optional RAID controller D
When you use Server Setup Tool to setup the server
with RAID controller D (MR466), the [Detailed Setup]
option may not setup right. To set RAID configuration
details with Server Setup Tool, use the following
procedure.
When the message [Press <Ctrl><M> to Run
MegaRAID Configuration Utility] is displayed during
the server boot, press [Ctrl]+[M]. After MegaRAID
Configuration Utility is started, set RAID
configuration in detail, and select [Logical
Drive]-[Advanced Menu]-[Write Policy], set
[WRTHRU] to the array that is installed on the OS.
For operation procedures about MegaRAID
Configuration Utility, refer to MegaRAID User's
manual.
After setting RAID configuration details, insert the
Server Setup Tool CD-ROM and the Startup Disk
floppy disk in the CD-ROM drive and the floppy disk
drive respectively, then restart the system to start
the Server Setup Tool.
4/15 S00047-EN EH02 Rev. E