2.11 Threshold Setting
E2-60
2.11 Threshold Setting
(Cont.)
7. Select the sensor to be adjusted by using the [FEED] key.
8. Press and hold the [PAUSE] key until more than 1.5 labels (tags)
have been issued.
The media will continue to be fed until the [PAUSE] key is released.
(An automatic threshold setting for the selected sensor is completed
by this operation.)
9. Press the [RESTART] key.
10. The printer returns to online mode.
Send an issue command from the host computer to the printer.
NOTES:
1. Failure to feed more than 1.5 labels may result in an incorrect
threshold setting.
2. While the Top Cover is raised, the [PAUSE] key does not work.
REFLECTIVE
B-SA4T V1.0A
TRANSMISSIVE
B-SA4T V1.0A
Black mark sensor
Feed gap sensor
NOTE:
A
paper end error cannot be detected during paper feed.