APPENDIX 1 SPECIFICATIONS ENGLISH VERSION EO1-33088
A1.3 Media
EA1- 5
A1.3.3 Detection Area of the Reflective Sensor
The Reflective Sensor is movable within the full range of the media width.
The reflection factor of the Black Mark must be 10% or lower with a waveform length of 950 nm.
The Reflective Sensor should be aligned with the centre of the Black Mark.
<Black Mark>
A1.3.4 Effective Print Area
The figure below illustrates the relation between the head effective print width and media width.
(for GS14 Type)
(for TS14 Type)
Min. 2 mm
Min. 8 mm
Sensor should be positioned at the
centre of the black mark.
Media feed direction
Detecting the black marks on the
back.
Sensor is movable within the full range.
2 mm
112.0 mm (Max. media width)
108.0 mm
±
0.2mm
(Head Effective Print Range)
Out of print range
Out of print range
Print head element
112.0 mm (Max. media width)
106.0 mm
±
0.2mm
(Head Effective Print Range)
Out of print range
Out of print range
Print head element
2 mm
3 mm 3 mm