Toshiba ETB004Z Network Card User Manual


 
E6581341
3
Wiring
Caution
Mandatory
Electrical construction work must be done by a qualified expert.
Installation or connection of input power by someone who does not have that expert
knowledge may result in fire or electric shock.
Shut off power when installing and wiring this option.
Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1) is
no longer lit.
Tighten the screws on the terminal block to the specified torque (Refer to Section 2.2).
If the screws are not tightened to the specified torque, it may lead to fire.
Operations
Warning
Prohibited
Do not pull on any cable itself.
Doing so could result in damage or malfunction.
Do not touch switches when the hands are wet and do not try to clean the inverter with
a damp cloth.
Doing so could result in electric shock.
Mandatory
Use this option under the environment specified in the instruction manual.
Usage under the environment other than them may cause damages or malfunctions or
an accident.
Use an additional safety device with your VF-AS1/PS1 or system to prevent a serious
accident due to the unit malfunctions.
Usage without an additional safety device may cause an accident.
Disposal
Caution
Mandatory
For safety's sake, do not dispose of the disused inverter yourself but ask an industrial
waste disposal agent (*).
If the collection, transport and disposal of industrial waste is done by someone who is
not licensed for that job, it is a punishable violation of the law. (Laws in regard to
cleaning and processing of waste materials)
(*) Persons who specialize in the processing of waste and known as “industrial waste
product collectors and transporters” or “industrial waste disposal persons.”
Notes on use
Notes
Do not install the inverter where the temperature or the humidity will change rapidly.
Keep a distance of 20cm or more between the inverter's power cable and the data
transmission cable.
Or the inverter might malfunction because of noise.
Insert a magnetic contactor or similar device between the VF-AS1/PS1 and the power
supply to ensure that power is turned off if an emergency stop command is entered
through the network.