- 8 -
EO1-19036
LS-780 SERIES
Cause Action
• The top window of the scanner is dirty or dewed. • Clean the top window.
• Barcode system does not correspond to scanner • Reading a barcode is unavailable. Use the barcode
specification. system corresponding to the scanner specification.
• Barcode has a defect. (Print of a barcode is too • Reading a barcode is unavailable.
light, dirty, blurred, or defaced.) Read a perfect barcode attached to the same article.
Enter the barcode of the article manually by the
keyboard.
(However, depending on the function of the host
terminal.)
• Angle to read a barcode is not appropriate. • Read the barcode at the appropriate angle. (Refer to
page 5 in details.)
• Barcode to be read is too near to the top window • Read the barcode in the effective scanning zone.
or too far from the top window. (Refer to pages 4 and 5.)
Cause Action
• The connector of the interface cable has been de- • Attach the connector securely.
tached.
• When the scanner cannot read a barcode...
When a trouble still exists after taking the actions described above, ask your TOSHIBA TEC representative.
• When the scanned data is not transferred to the host terminal...
When a trouble still exists after taking the action described above, ask your TOSHIBA TEC representative.
8. SPECIFICATIONS
8.1 Scanner Main Body
Dimensions: 200 (W) x 90 (D) x 220 (H) mm (Vertical standing dimensions)
Weight: 1.5 kg
Readable code: EAN/JAN-13, EAN/JAN-8, UPC-A, UPC-E, EAN128,
EAN-13/8 and UPC-A/E with Supplemental 2 or 5 digits,
ITF (Interleaved 2 of 5), NW7 (CODABAR),
CODE39, CODE93, CODE128
Interface: OCIA
RS-232C
USB
Reading Height: Up to 200 mm above from the Scanner Window surface
Input Power: 12 VDC – 10%
8.2 Interface Cable (Option)
Cable Length: 5.0 m