Toshiba TLP-470 Projector User Manual


 
CONTENTS
40
Maintenance
If there is some problem inside the projector,
the indicators light up or flash.
Trouble indications
ON Off or lit (red)
LAMP
TEMP
The power does not come on.
Malfunction of the unit.
Unplug the power cord and call the
dealer.
ON Lit (red)
LAMP Lit (red)
TEMP
The lamp turns off or does not light up.
The lamp’s end, or malfunction of the
unit.
Lamp’s life length is over, replace the
lamp with new one.
42
Unplug the power cord and call the
dealer.
ON Lit (red)
LAMP
TEMP Lit (red)
The power turns off or does not come on.
The inside is too hot, or the projector has
been working in an area of high
temperature.
Place the projector correctly so the
intake and exhaust fans’ holes are not
covered.
Turn the projector off, and leave it for
a while, and turn it on again.
Clean the air filter.
41
ON Lit (red)
LAMP
TEMP Flashing (red)
The power turns off or does not come on.
Trouble with the intake fan.
Unplug the power cord and call the
dealer.
ON Lit (red)
LAMP
TEMP Flashing (orange)
The power turns off or does not come on.
Trouble with the exhaust fan.
Unplug the power cord and call the
dealer.
Note
Before attempting any maintenance, unplug the
power cord.
ON Indicator
LAMP Indicator
TEMP Indicator
ON/STANDBY MENU ENTER
SELECT/ADJUST
INPUT
ON
LAMP
TEMP