Transition Networks SISTF1010-150-LR(T) Switch User Manual


 
Transition Networks SISTF1010-150-LR(T) Industrial Unmanaged Switch
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
16
Connecting copper cables
Copper cable
installation
To connect the copper cable to the Industrial Switch and other equipment, do the following:
Step Action
1. Locate or build 10Base-T or 100Base-TX copper cables with male, RJ-45
connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on
the Industrial Switch. See Figure 12 below.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45
port on the other device (switch, workstation, PLC, etc.).
4. Check the copper port LED on the Industrial Switch to verify the connection—
LNK/ACT LED should be lit.
Figure 12: Copper Cable Installation
Copper cable
configuration
Either a straight-through or cross-over cable may be used. See Figure 13.
Figure 13: Straight-Through and Crossover Cables
Note: The AutoCross
TM
feature determines the characteristics of the cable connection and
automatically configures the unit to link up, regardless of the cable configuration,
allowing either straight-through (MDI) or crossover (MDI-X) cables to be used.
(Requires no operator intervention.). See Advanced Features section for more
information.