Tripp Lite 200703079 Power Supply User Manual


 
Surge-Only Protected Outlets: Provide surge and line noise
protection, not battery backup. Plug equipment that does not require
battery backup during a utility power failure (such as a printer,
scanner or fax machine) into these outlets.
Battery Backup Protected/Surge Protected Outlets: Provide both
battery backup and surge protection. Plug your computer, monitor and
other critical equipment into these outlets. NOTE: DO NOT PLUG
LASER PRINTERS INTO THESE OUTLETS.
USB Communication Port: This port can connect your UPS to a
computer in order to automatically save open files and shut down the
computer if it is left unattended during an extended power failure. Use
with Tripp Lite's PowerAlert Software and appropriate USB cable. A
PowerAlert CD and/or USB cable are included with select models. If
PowerAlert is included with your model, insert the CD into the CD
tray of your computer and follow the installation instructions. If
PowerAlert Software and/or the appropriate cable did not come with
your UPS, you can obtain the software FREE via the Web at
www.tripplite.com. Any user-supplied USB cable may be used to
connect your UPS to your computer. Note: This connection is option-
al. The UPS will work properly without this connection. Also Note:
This UPS System automatically provides basic communication com-
patibility with many integrated Windows
®
, Macintosh
®
and Linux
®
power management applications.
Tel/DSL Protection Jacks (select models only): RJ-style jacks pro-
tect connected equipment by stopping surges on a single phone, fax or
modem line. Connect a phone cord from the wall jack directly to the
Tel/DSL jack labeled “IN.” Connect a phone cord from the Tel/DSL
jack labeled “OUT” directly to the device to be protected. The UPS
system must always be the first item connected in line from the wall
jack. The UPS system must be plugged into a 3-wire grounded AC
outlet for Tel/DSL line surge protection to work. Connecting your
equipment to these jacks is optional. Your UPS will work properly
without this connection.
Coaxial Protection Jacks (select models only): Gold-plated coaxial “F”
connectors protect connected equipment by stopping surges on a single
DSS satellite, cable or antenna line. Connect a coaxial cable from the wall
jack directly to the coaxial jack labeled “IN.” Connect a coaxial cable
from the coaxial jack labeled “OUT” directly to the device to be protect-
ed. The UPS system must always be the first item connected in line from
the coaxial wall jack. The UPS system must be plugged into a 3-wire
grounded AC outlet for coaxial line surge protection to work. Make sure
cables connected to satellite dishes, antennas, etc. are also grounded.
Connecting your equipment to these jacks is optional. Your UPS will
work properly without this connection.
Battery Replacement (not shown): Under normal conditions, the
original battery in your UPS will last several years. Battery replace-
ment should be performed only by qualified service personnel.
During battery replacement, qualified service personnel should refer
to “Battery Warnings” in the Safety section and should observe the
following procedure: turn the UPS off, unplug the power cord and
remove the two screws on the UPS back panel to access the internal
battery. Tripp Lite offers a complete line of replacement batteries at
www.tripplite.com.