Overvoltage
correction
Input voltages between 245 and 274V AC are reduced by 9%
Direct pass through Input voltages between 200 and 244V AC are passed through unchanged
Brownout correction Input voltages between 183 and 199V AC are boosted by 10%
Severe brownout
correction
Input voltages between 156 and 182V AC are boosted by 21%
LEDS ALARMS & SWITCHES
Front panel LEDs Yes, includes 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage
regulation status, UPS load level and replace battery warning
Alarms 3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous
short beeps) and low battery (continuous tone)
Switches Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
SURGE / NOISE SUPPRESSION
AC surge suppression 340 joules
AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Shipping weight (lbs) 48.8
Shipping weight (kg) 22
Shipping Dimensions
(HWD/in)
18.5 x 12.2 x13.4
Shipping Dimensions
(HWD/cm)
46.9 x 31 x 34
Unit weight (lbs) 45.5
Unit weight (kg) 20.5
Unit Dimensions
(HWD/in)
12.7 x 7.5 x 9.1
Unit Dimensions
(HWD/cm)
31.75 x 19.1 x 23.1
Material of
construction
PVC
Form factors
supported
Tower
Cooling method UPS cooling via rear-exit fan
Battery Access Battery access door allows hot swap battery replacement without powering connected equipment off
ENVIRONMENTAL
Relative Humidity 0 to 95%, non-condensing
COMMUNICATIONS
Network monitoring
port
Includes 2 built-in monitoring ports, 1 USB & 1 DB9
Software and cabling
included
PowerAlert UPS monitoring software is included on CD-ROM for all common network and standalone operating
systems. Ships with 2 cables, 1-USB to USB & 1-DB9 to DB9
LINE / BATTERY TRANSFER
Transfer time from
line power to battery
mode
2-4 milliseconds
Low voltage transfer
to battery power
155V (resets to line power as voltage increases to 163V)