Tripp Lite SU1500RTXL2UA Power Supply User Manual


 
PowerAlert Software and cabling
Mounting hardware for 4 post rack enclosures
Instruction manual with warranty information
Features
SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all
usage conditions
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other
UPS types
Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 100/110/120V (+/-2%) values
Standard internal battery set offers 14 min. runtime at half load (600W) and 5 min. at full load (1200W)
Optional BP48V24-2U external battery pack increases runtime (limit 1)
Optional BP48V60RT3U external battery pack increases runtime (multi-pack compatible)
Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 19 in.
Ships with all mounting accessories for 4-post rackmount installation
Optional 2POSTRMKITWM enables 2-post rackmount or wallmount installation
Optional 2-9USTAND accessory enables small-footprint upright tower placement
Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure
and requires maintenance
Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus
any number of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current,
battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS
nominal voltage adjustment and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
NEMA 5-15P input plug; NEMA 5-15R output receptacles
Integrated 2-bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (bank one
has 2 outlets, bank two has 4 outlets)
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required
Supports 2-post rackmount installation with optional 2POSTRMKITWM accessory
Single-line tel/DSL or network Ethernet surge suppression
2-year manufacturer's product warranty; $250,000 Ultimate Lifetime Insurance
Specifications
SYSTEM OVERVIEW
Voltage
compatibility
120V AC (100/110/120V)
Frequency
compatibility
50/60 Hz compatible (auto-sensing)
OUTPUT
Output VA 1500
Output watts 1200
Output nominal
voltage
120V AC (100/110/120V)
Output voltage
regulation
Maintains full-time sine wave output within 2% of selected nominal, less than 3% total harmonic distortion (linear load) /
5% total harmonic distortion (computer load) (Less than 5% THD on-line and on-battery)
Output frequency
regulation
Regulates line frequency to 50/60Hz +/- 0.05Hz
Outlet quantity /
type
6 x NEMA 5-15R