Tripp Lite SU1500RTXL2UA Power Supply User Manual


 
Customized load
management
receptacles
2 controllable load banks support load shedding and remote reboot on demand of locked network devices (bankone has 2
outlets, bank two has 4 outlets)
Overload
protection
20A input breaker
INPUT
Maximum input
amps
12A
Input connection
type
NEMA 5-15P
Input cord length 10 ft./3m
Recommended
Electrical Service
120V 15A
BATTERY
Full load runtime 5 min. with internal batteries (1200W)
Half load runtime 14 min. with internal batteries (600W)
Expandable
battery runtime
Supports extended runtime with optional external battery pack BP48V24-2U (limit 1) and BP48V60RT-3U (multi-pack
compatible)
DC system voltage 48VDC
Typical battery
lifespan
3-6 years, depending on usage
Battery recharge
rate
Less than 5 hours to 90%
Replacement
Battery Cartridge
RBC94-2U
VOLTAGE REGULATION
Voltage regulation
description
On-line, double-conversion power conditioning maintains output within 2% of 100/110/120 volts at all times
Overvoltage
correction
Maintains output of selected nominal +/-2% during overvoltages to 138V AC
Brownout
correction
Maintains output of selected nominal +/-2% during undervoltages to 65V AC (at loads greater than 70% undervoltage
correction extends to 80V)
LEDS ALARMS & SWITCHES
Front panel LEDs LED STATUS DISPLAY: line power (green), on-line (green), bypass (yellow), on battery (green), overload (red), battery
low (yellow) - 4 LED LOAD / BATTERY LEVEL DISPLAY (100%, 75%, 50%, 25%). LED display panel easily rotates for
better viewing in rackmount or tower configurations.
Alarms Multi-function audible alarm with distinctive ring patterns offer notification of backup operation (2 seconds on/0.5 seconds
off), low battery warning (1.25 seconds on/0.5 seconds off), overload (sounds continuously), UPS fault (4.2 seconds on / 1
second off), input voltage out of frequency (2.1 seconds on/0.14 seconds off) and high input voltage (2.1 seconds on/0.07
seconds off)
Switches Includes power off/on switch to enable system turn on (press ON switch), UPS battery test (press ON switch during normal
AC operation), buzzer silence (press ON switch during battery operation) and OFF (press OFF switch) - all switch functions
require that the switch be pressed and held for longer than 2 seconds, but less than 4 seconds
SURGE / NOISE SUPPRESSION
AC surge
suppression
480 joules
AC suppression
response time
Instantaneous
Dataline
suppression
Set of 8-wire RJ style interface jacks offer surge suppression for network ethernet or TEL/DSL connection. Pins 1,2,3 and
6 offer ethernet protection starting at 7.5V and the center two wires, pins 4 & 5, offer TEL/DSL line suppression starting at
260V
EMI / RFI AC noise
suppression
Yes
PHYSICAL