Tone Lock (out) mode
You can lock a particular subaudible tone. The scanner won't stop on any transmissions
which have the locked out subaudible tone.
To select the SQ mode:
1. Press
MENU.
2. Select
3:SYSTEM OPTION / 8:SQ MODE by rotating the VFO and pressing E.
3. Rotate the
VFO to select one the type from (1:CSQ, 2:TONE SQ, 3:TONE
SEARCH
) and press E.
4. To set Tone Lock mode, do the following first, then select
2:TONE SQ in step 3.
1) For Scan mode, select
2:SCAN OPTION - select the channel number - / 3:TONE
DATA
/ 1:CTCSS or 2:DCS by rotating the VFO and pressing E, than press L/O.
2) For Search mode, select
1:SERVICE OPTION / :CHAIN SEARCH /
5:TONE DATA / 1:CTCSS or 2:DCS by rotating the VFO and pressing E, than
press
L/O.
Remember! You can also use or instead of rotating the VFO.
Also instead of pressing
E, you can press the VFO control.
Note: To unlock the tone, press E instead of pressing L/O on step 1) or 2).
CTCSS: Continuous Tone Coded Squelch System.
DCS: Digital Coded Squelch.
When Search mode and Tone Search are selected, the display shows the
frequency and tone data alternately.
If the delay feature (-2 sec/-5 sec/-10 sec) has been set while in Tone search
mode, it resumes scanning according to the delay period.