Unisys NX5820 Server User Manual


 
Configuring Optional and Recommended UPS
7017 6300005 655
If a site UPS is not used, Unisys highly recommends at a minimum that a small individual
UPSs provided power and status connections to each SCP in the system (2 UPS for
redundant SCP). For this application, a small UPS can be obtained from Unisys Direct
(Model PRC1000i) to supply power and status for each SCP. The interconnect box/power
and status cable is provided with the SCP. See Figure 613 and Figure 614 for SCP to
UPS cabling.