ViewEra V141 Computer Monitor User Manual


 
10
User Setting Area
The user settings by the user on the last display mode maintain in the memory
of the micro-controller. You can change the settings or add a nonstandard mode.
The micro-controller always detects and displays the last mode stored in the user
setting area when the monitor is turned on.
Factory Presetting Area
There are some preferred display modes preset in the micro-controller. These
display modes are preset at the factory and include the most popular display
modes currently available. The micro-controller searches for a proper display
mode in this area if it fails to find a proper display mode in the user setting
area.
MODE
Resolution
(Dots*lines)
Horizontal
Freq.(KHz)
Vertical
Freq.(Hz)
Remark
1.
VGA 640×480 31.5 60 Non-interlaced
2.
VESA/60 800×600 37.9 60 Non-interlaced
3.
VESA/60 1024×768 48.4 60 Non-interlaced
5. Signal Connector Pin-outs
To connect VGA, 8514A or IBM-compatible graphics adapters, use a 15 pin