Viking PSFEM1xxxGQxxx Computer Drive User Manual


 
Manual
9/11/2014
PSFEM1xxxGQxxx
Viking Technology
Revision B
Page 14 of 33
www.vikingtechnology.com
2.2.1 STANDBY IMMEDIATE Command
The Power-On-to-Ready time assumes a proper shutdown (power removal
preceded by STANDBY IMMEDIATE command. A STANDBY IMMEDIATE
before power down always performs a graceful shutdown and does not require
the use of the hold-up circuit. Note that SMART attribute 174 "Unexpected Power
Loss" records the number of non-graceful power cycle events.
Table 2-4: STANDBY IMMEDIATE Timing
Power Cycle Endurance
Min
Max
Unit
STANDBY IMMEDIATE to WE completed
-
72.9
ms
Notes:
1. From Standby Immediate command to NAND Write Protect enable.
2.3 Electrical Characteristics
2.3.1 Absolute Maximum Ratings
Values shown are stress ratings only. Functional operation outside normal
operating values is not implied. Extended exposure to absolute maximum ratings
may affect reliability.
Table 2-5: Absolute Maximum Ratings
Description
Min
Max
Unit
Maximum Voltage Range for Vin
-0.2
6
V
Maximum Temperature Range
-40
85
c
2.3.2 Supply Voltage
The operating voltage is 5V.
Table 2-6: Operating Voltage
Description
Min
Max
Unit
Operating Voltage for 5.0 V (+/- 5%)
4.75
5.25
V
Table 2-8: Current Draw – SATA
Mode Typical
1
Unit
Read/Writes (Average RMS)
215 / 310
mA
Idle
25
mA
Slumber
10
mA
Notes:
1. Measured using 16GB SLC, VRFEM1016GQCQS