Western Telematic Data/FaxModem Network Card User Manual


 
6. S-Registers
Note: To change a setting, use the ATSr=n command,
where r is the register and n is a decimal value from 0-255
(unless otherwise indicated).
Register Default Function
S0 1 Sets the number of rings on which to answer in Auto
Answer Mode. When set to 0, Auto Answer is
disabled. See DIP Switch 5 (Section 4.2).
S1 0 Counts and stores the number of rings from an
incoming call. Register S0 must be greater than 0.
S2 43 Stores the ASCII decimal code for the escape code
character. The default character is +. A value of 128-
255 disables the escape code.
S3 13 Stores the ASCII code for the Carriage Return
character. Valid range is 0-127.
S4 10 Stores the ASCII decimal code for the Line Feed
character. Valid range is 0-127.
S5 8 Stores the ASCII decimal code for the Backspace
character. A value of 128-255 disables the Backspace
key's delete function.
S6 2 Sets the number of seconds the modem will wait
before dialing. If Xn is set to X2 or X4, S6
determines the timeout length when no dial tone is
detected.
S7 60 Sets the number of seconds the modem will wait for a
carrier. Often used to select a longer duration when
the modem is originating an international connection.
S8 2 Sets the duration (in seconds) for the Dial command
pause option (,).
S9 6 Determines the length of time (in tenths of a second)
the remote modem’s carrier signal must continue in
order to be recognized by the RMM.
S10 7 Sets the length of time (in tenths of a second) the
modem will wait after loss of carrier before hanging
up. Allows the modem to distinguish between a line
hit (or other momentary break) from a true disconnect
(hang up) by the remote modem.
Page 16
RMM User’s Guide