Xantech HD44C Switch User Manual


 
08905071B - 4 -
RS232 COMMAND STRUCTURE
Where:
{CR#} – Carriage Return (0x0D)
{z#} - Zone Number. Range is 1..4 (1..16 if expanded)
{s#} - Source Input Number. Range is 1..4
{0/1} – Either 0 (zero) or 1 (one). 0 – Off, 1 – On.
NAME COMMAND RETURN
REMARKS
!{z#}PR01+
To turn on Zone 2: !2PR1+ or !02PR1+ or
!2PR01+ or !02PR01+
Zone Power
!{z#}PR00+
OK{CR}
ERROR{CR}
To turn off Zone1: !1PR0+ or !01PR0+ or
!1PR00+ or !01PR00+
Zone Power
Toggle
!{z#}PT+
OK{CR}
ERROR{CR}
All Zones Off
!EO+
OK{CR}
ERROR{CR}
Turns all the zones off.
All Zones On
!EA+
OK{CR}
ERROR{CR}
Turns all the zones on.
Zone Restore All
!RF+
OK{CR}
ERROR{CR}
Restore all the Zone-to-Source routing to the
current selection: !RF+
Input (Source)
Select
!{z#}SS{s#}+
OK{CR}
ERROR{CR}
To set Zone 1 to Source Input 4: !1SS4+
Ping Expansion
Port
!RP+
OK{CR}
ERROR{CR}
Request that any unit connected to the expansion
port respond with a ping.
Return Ping to
Xantech port
!SP+ +
Returns a +. Meant for inter-expansion box
communications.