Xantech HD44C Switch User Manual


 
08905071B - 7 -
[9] CAT5 ZONE OUTPUT
Output connection to the HDRXSG01 receiver module. Uses standard CAT5 cable. Be sure to verify
CAT5 wiring connection is correct before installation.
[10] COAXIAL ZONE OUTPUT
Gold-plated RCA jacks for connection to an HD monitor. Color coordinated to match all HD type
products. The CAT5 and coaxial output can be used at the same time.
IMPORTANT NOTICE
After connecting the CAT5 cable to the receiver (HDRXSG01), the
power supply to the receiver should be unplugged for a few seconds
and then reconnected. This allows the receiver to go through the full
process of line length and line quality self-calibration.
Do not connect the power supply to the receiver until after the CAT5
connection. The HD44CC5 must be powered on before the
HDRXSG01.
As an alternate process to this procedure, the power may be cycled
off for a few seconds and reapplied to accomplish the same full self-
calibration process.
If for some reason the system losses power at the receiving end
(HDRXSG01), the transmitting end (HD44CC5), or both ends, the full
self-calibration process will automatically occur.