Basic Operation
975-0288-01-01 2–9
Changing Charging Settings
Default Setting The PowerHub 1800 is set at the factory to default to the 40 A Charging
Profile. In the event that one of the other profiles are required, follow the
instructions below to change the setting.
Setting the
Selection
To set the selection to the desired profile, stop pressing the Select Button
when the desired profile is displayed. The unit will set the profile shown
in the display, then will return to the default screen within 10 seconds.
Returns to
Default
The charging setting will revert to the 40 A default setting whenever the
ON/OFF Button is pressed or all DC input sources are removed and utility
AC is not available.
Figure 2-5
Input Displays
Press and hold for approximately
3-5 seconds.
The AC LED will start to flash.
Press again within 10 seconds.
Display shows default
charge setting (40A)
The Charge Setting changes
to the 10 A profile.
The Charge Setting changes to the
0 A profile. This profile completely
turns off the charging feature.
Press again within 10 seconds.