16 port 10/100 Ethernet Switch
Troubleshooting
If the 16 port Switch is not functioning properly, make sure
the 16 port Switch was set up according to instructions in this
manual.
The Power LED is not lit
Solution:
a. Check if the AC power cord is well connected. Try to
unplug and plug back the power cord to the LAN Switch or
try another power cord.
b. Check if the AC power source is in good condition.
The Link LED is not lit
Solution:
a. Make sure the Switch configuration is consistent with the
connecting device
c. Check the cable connections.
d. Make sure the cable distance between 16/24 port
Switch and other IEEE802.3 compatible network device
should not exceed 100 meter. Performance is bad
Solution:
a. Check the full duplex status of the Ethernet Switching. If
the Ethernet Switching is set to full duplex and the partner is
set to half duplex, then the performance will be poor.
b. Make sure the cable between the switch and other
IEEE802.3 compatible network device is Category 5 UTP at
100Mbps operation.
Some stations can not talk to other stations located on
the other port
Solution:
a. Check status of the LNK LED to make sure the link is
correct.
b. Make sure that the workstation's network configuration is
correct, modify the network configuration of workstation if
need.
c. Please reset the switch if need.
1-9 Trouble Shooting