ICP-CC404 | Installation Guide | 3.0 Codepad Indicators
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 17
Table 12: FAULT Indicator
Indicator Definition
On A system fault must be corrected
Off The system is normal (no faults)
Flashing A system fault must be acknowledged
Audible Indicators
The codepad provides these audible indications:
Table 13: Audible Indicators
Audible Indicator Definition
One short beep A button was pressed on the
codepad, or Exit Time ended when
arming in STAY Mode 1 or STAY
Mode 2
Two short beeps The system accepted the code
Three short beeps The system executed the requested
function
One long beep Exit Time ended when arming in
AWAY Mode, or the requested
operation was denied or aborted
One short beep
every second
Walk Test Mode is currently active,
or warning before automatic arming
takes place
One short beep
every 2 sec
Telephone Monitor Mode is active.
One short beep
every minute
There is a system fault to
acknowledge
3.2 ICP-CP508LW Eight Zone LCD
Codepad
Figure 2: ICP-CP508LW Eight Zone LCD
Codepad
The codepad is the communications interface
between you and the alarm system. The codepad
allows you to issue commands and offers visual and
audible indications to guide you through general
operation.
The codepad uses a number of indicators: eight zone
indicators show the condition of each zone and seven
other indicators show general status. These indicators
are described in this section.
Zone Indicators
1 2 3 …
The zone indicators (1 to 8) show the
status of the zones as listed in Table 8 on
page 16.
AWAY Indicator
The AWAY indicator lights when the
system is armed in AWAY Mode. The
ON indicator also lights when the
system is armed in AWAY Mode (refer
to Table 10 on page 16).
The AWAY indicator flashes with the STAY
indicator when you are in Installer’s Programming
Mode or you are using a Master Code function.
Refer to Section 4.1 Arming the System in AWAY Mode
on page 18 for more information.
STAY Indicator
The STAY indicator lights when the
system is armed in STAY Mode 1 or
STAY Mode 2 (refer to Table 9 on
page 16).
The STAY indicator also flashes with the AWAY
indicator when you are in Installer’s Programming
Mode or you are using a Master Code function.
The ON indicator also lights when the system is
armed in STAY Mode 1 or STAY Mode 2.
For more information, refer to:
Section 4.3 on page 19 to arm the system in
STAY Mode 1.
Section 14.3.4 on page 57 to set zones to
automatically isolate in STAY Mode 1.
Section 4.5 on page 20 to arm the system in
STAY Mode 2.
Section 6.1.4 on page 30 to use the Installer Code
to set zones to automatically isolate in STAY
Mode 2.
Section 6.2.5 on page 35 to use the Master Code
to set zones to automatically isolate in STAY
Mode 2.
System Disarmed
This indicator lights with the OFF
indicator when the system is disarmed.
MAINS Indicator
The MAINS indicator shows when the
systems AC MAINS supply is normal or
failed (refer to Table 11 on page 16).
When programming in Installer’s Programming
Mode or using a Master Code function, the MAINS
indicator lights to indicate a location value from 10 to
15. The MAINS indicator represents the 10 digit,
which is added to the value of the lit zone indicator
(for example, if the value programmed in a location is
12, the MAINS and Zone 2 indicators light).