ICP-CC404 | Installation Guide | 18.0 System and Consumer Options
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 73
Table 61: System Date Parameters
Location Parameter Default
905 Day of the month (tens digit) 0
906 Day of the month (units digit) 1
907 Month of the year (tens digit) 0
908 Month of the year (units digit) 1
909 Current year (tens digit) 0
910 Current year (units digit) 1
The ICP-CC404 Control Panel has a real-time
12-month calendar you must set during installation,
and reset every time power is removed from the
system.
A Master Code holder can also set the System Date
and Time (refer to Section 6.2.7 Setting the Date and
Time on page 36).
18.0 System and Consumer
Options
The locations in this section have up to four options.
You can select any combination of these options by
programming a single value. Calculate this value by
adding the option bit numbers together. Refer to
Section 2.3 Programming Option Bits on page 10 for
more information.
18.1 System Options 1
Program the selected System Options 1 in
Location 424.
The default value is 1.
The options are:
1 – Smart Lockout Allowed
This feature allows the control panel to remove any
zones that are programmed for lockout dialer from
the lockout list when the sirens are running. This
feature allows a monitoring station to receive zone
alarm reports from previously locked out zones
during siren time. Refer to Section 14.3.4 Zone
Options 1 on page 57 for information on programming
zones for lockout dialer and lockout siren.
Refer to Section 14.5 Swinger Shutdown Count for Dialer
on page 59 to program the number of times the zone
can send a report before being locked out.
2 – Horn Speaker Monitor
If this option is selected, the control panel detects
when the horn speaker is disconnected from the
speaker terminals. The FAULT indicator lights when
the horn speaker is disconnected and turns off when
the horn speaker is reconnected.
If an output must operate when the horn speaker is
disconnected, use Output Event Type 1,6 Horn
Speaker Monitor Fail (refer to this option on page 66
for more information).
4 – Strobe Indications for Radio Arm/Disarm
This option allows the strobe to indicate when the
system is armed and disarmed when remotely
operating the system using the WE800E Wireless
On/Off Interface. Refer to Table 62.
Table 62: Strobe Indications for Remote
Operations
Strobe Duration System Status
3 sec System disarmed
6 sec System armed in AWAY Mode
6 sec System armed in STAY Mode 1
8 – Horn Speaker Beeps for Radio Arm/Disarm
This option enables the horn speaker to sound when
the system is armed or disarmed remotely using the
WE800E Wireless On/Off Interface. Refer to Table
63.
Table 63: Horn Speaker Indication Beeps for
Remote Operations
Beeps System Status
1 System disarmed
2 System armed in AWAY Mode
1 two-tone beep System armed in STAY Mode 1
18.2 System Options 2
Program the selected System Options 2 in
Location 425.
The default value is 0.
The options are:
1 – Silent Codepad Panic
If this option is selected, a Codepad Panic Alarm or
Radio Remote Panic Alarm does not operate the
horn speaker, the bell, or the strobe outputs. If this
option is not selected, all three outputs operate after a
Codepad Panic Alarm is activated when a user
presses [1] and [3] or [STAY] and [AWAY] at the
same time on the remote codepad. Selecting this
option does not affect the operation of the
communication dialer.
If you want to disable reporting of a Codepad Panic
Alarm, program Locations 337 and 338 as 0 (refer to
Section 15.9 Codepad Panic Report on page 61).
2 – Silent Codepad Fire
If this option is selected, a Codepad Fire Alarm does
not operate the horn speaker, the bell, or the strobe
outputs. If this option is not selected, all three outputs
operate after a Codepad Fire Alarm is activated when
a user presses [4] and [6] at the same time on the
remote codepad. Selecting this option does not affect
the operation of the communication dialer.