390 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
Port specifications for all router models
9
Storage environment
Table 66 provides the storage environment specifications for the Brocade NetIron XMR routers.
Safety agency approvals
• CAN/CSA-C22.2 No. 60950-1-07/UL60950-1 – Second Edition, Safety of Information
Technology Equipment
• EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and
User’s Guide
• EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications
Systems
• EN 60950-1:2006\IEC 60950-1:2005, Second Edition, Safety of Information Technology
Equipment
Electromagnetic approvals
• FCC Part 15, Subpart B (Class A)
• EN 55022 (CE mark) (Class A)
• EN 55024 (CE mark) (Immunity) for Information Technology Equipment
• ICES-003 (Canada) (Class A)
• AS/NZ 55022 (Australia) (Class A)
• VCCI (Japan) (Class A)
• EN 61000-3-2
• EN 61000-3-3
• EN 61000-6-1
Port specifications for all router models
This section describes port specifications for all router models.
Console port pin assignments
The console port is a standard male DB-9 connector, as shown in Figure 252. For information
about how you can use this port, refer to “Console port” on page 20.
TABLE 66 Brocade NetIron XMR router storage environment requirements
Storage temperature Storage humidity Storage altitude
(-25° – 70° C) -13°– 158°F 95% maximum relative humidity,
non-condensing
(0 – 4500 meters) 0 – 15,000 ft