2. WIRING
Refer to the interconnection diagram at the back of this manual to connect cables.
Precautions for cable installation
Observe the following guidelines to prevent noise, interference problem.
The transducer cable carries very weak signals (amplitude less than 0.1 μV), which
are easily interfered by noise. The need for a good ground cannot be overempha-
sized.
Locate DS-60 cables away from the transmission antenna cable or radio equip-
ment.
Locate the DS-60 cables away from the power cables mentioned below. Also, sep-
arate cables at least 400 mm when the cables are run parallel with power cables.
Cable carrying more than a few kilowatts power to fluctuating loads
Cable carrying switching waves generated by thyristor, etc.
TTYCYS-4 or TTYCS-4
(Max. 150 m)
Distributor
DS-610
Display Unit
(main)
DS-600
Remote Controller RD-501/
Dimmer Controller RD-502
TTYCYS-4
Transducer cable
(30 m/40 m/50 m/60 m)
Transducer
DS-630/631
Transceiver Unit
DS-620
Junction Box
DS-640 (option)
TTYCY-4S*
TTYCY-4S*
DPYCY-4.0*
DPYCY-4.0*
*The cable length between DS-620 and DS-610 must be less than 500 m.
Note: For details of JIS (Japan Industrial Standard) cables, see APPENDIX 2.
100-240 VAC
(DPYC-2.5)
ANALOG VOLTAGE OUT (TTYCS-1)
ANALOG CURRENT OUT (TTYCS-1)
KP IN/OUT (TTYCS-1, x2)
ALARM SYSTEM
A
NALOG METER OUT (TTYCYS-1Q, x2)
DIGITAL OUT
DIGITAL OUT
IEC61162/IN (TTYCS-1, x3)
IEC61162/OUT (TTYCS-1, x5)
Display Unit (sub) DS-600, RD-20/50 (x5)
LOG/CONTACT, 200 pulse (DPYCY-1.5, x4)
DS-340
(CO-SPEVV-SB-C)