By continuing to press the
DATA
button, you can scan
through four displays of operational information. This
data appears in the bottom portion of the display area.
REMAINING CAPACITY—
This is the percentage
of water softening capacity remaining. Immediately after
a regeneration, 100% shows. As water is used, the
percentage decreases until the next regeneration.
During regenerations, the percentage increments upward.
NOTE:
Zero(%) shows until after the first regeneration
begins, after connecting to electrical power.
FLOW RATE, GPM—
When using soft water, this
display shows the flow rate passing through the softener
(in gallons per minute). Zero shows if water is not passing
through the water softening system.
GALLONS TODAY—
Each day, beginning at
midnight, the timer keeps a running count of the total
gallons of water that have passed through the water
softening system.
AVG. DAILY GALLONS—
The figure displayed is
the average gallons of water used by the household each
day over the past seven day period.
NOTE:
If preferred, you can set the timer to show the
reading in liters instead of gallons. If
GALLONS TODAY
or
AVG. DAILY GALLONS
exceeds 1999, a (x10) indicator
appears. This means you must multiply the number shown
by ten.