A SERVICE OF

logo

By continuing to press the
DATA
button, you can scan
through four displays of operational information. This
data appears in the bottom portion of the display area.
REMAINING CAPACITY
This is the percentage
of water softening capacity remaining. Immediately after
a regeneration, 100% shows. As water is used, the
percentage decreases until the next regeneration.
During regenerations, the percentage increments upward.
NOTE:
Zero(%) shows until after the first regeneration
begins, after connecting to electrical power.
FLOW RATE, GPM
When using soft water, this
display shows the flow rate passing through the softener
(in gallons per minute). Zero shows if water is not passing
through the water softening system.
GALLONS TODAY
Each day, beginning at
midnight, the timer keeps a running count of the total
gallons of water that have passed through the water
softening system.
AVG. DAILY GALLONS
The figure displayed is
the average gallons of water used by the household each
day over the past seven day period.
NOTE:
If preferred, you can set the timer to show the
reading in liters instead of gallons. If
GALLONS TODAY
or
AVG. DAILY GALLONS
exceeds 1999, a (x10) indicator
appears. This means you must multiply the number shown
by ten.
Customer ServiceTroubleshooting TipsOperating InstructionsSafety Information
13
Feature: Other Data Displays
WATER MANAGEMENT SYSTEM
AVG. DAILY GALLONS
WATER MANAGEMENT SYSTEM
GALLONS TODAY
WATER MANAGEMENT SYSTEM
GPM
FLOW RATE
CAPACITY
%
WATER MANAGEMENT SYSTEM
REMAINING CAPACITY
FLOW RATE (GPM)
GALLONS TODAY
DATA
AVG. DAILY GALLONS