15
Service: Manually Initiated Electronic Diagnostics
To enter diagnostics, press and hold the
DATA
button until the display appears as shown.
NOTE:
If the water softening system is in the middle of a
regeneration, top part of the display shows the cycle of
regeneration and minutes of the cycle remaining. If two
cycle names are flashing, the valve is in transition
between the cycles.
A
The three digits under
WATER MANAGEMENT
SYSTEM
indicate water meter operation as follows:
■ 000 (steady) = soft water not in use…no flow
through the meter.
—OPEN A NEARBY SOFT WATER FAUCET—
■ 000 to 199 (continual) = repeats display for
each gallon of water passing through the
meter.
If you don’t get a reading in the display, with
faucet open, pull the sensor from the valve outlet
port. Pass a small magnet back and forth in front
of the sensor. You should get a reading in the
display. If you get a reading, unhook the in and
out plumbing and check the turbine for binding.
1
Motor
Turbine
Turbine
support &
shaft
Position
switch
Valve
outlet
Sensor
housing