![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/3d/03db881b-7fae-4095-aa41-0a6dca6a2dfd/03db881b-7fae-4095-aa41-0a6dca6a2dfd-bgd.png)
Pressure Relief Procedure
311511G 13
Pressure Relief
Procedure
1. Turn off feed pumps and agitator if used.
2. Turn PARK/RUN switch to PARK.
3. Trigger gun to relieve pressure.
4. Turn off air inlet valve.
5. Engage gun piston safety lock.
6. Verify gun fluid manifold valves A and B are closed.
7. Close pump inlet supply valves.
Flushing
• Flush out old fluid with new fluid, or flush out old
fluid with a compatible solvent, such as toluene,
naptha, or mineral spirits before introducing new
fluid.
• Use lowest possible pressure when flushing.
• To flush entire system, circulate through gun fluid
manifold (with manifold removed from gun).
• Always leave hydraulic oil or a non-water based,
non-water absorbent fluid in system. Do not use
water.
ti2409a
ti2421a
Flush equipment only in a well-ventilated area. Do not
spray flammable fluids. Do not turn on heaters while
flushing with flammable solvents.
Only use flush solvents that are compatible with Fluo-
roelastomer seals. Non-compatible solvents will dam-
age seals and cause hazardous conditions, such as
high pressure leaks and pressure switch failure.