A SERVICE OF

logo

2-16
Installing the Switch
Installation Procedures
Installing the Switch
LEDs
The RPS LEDs are located on the back of the RPS/EPS. These LEDs are
duplicated on the front of the device. The following graphic shows an example
of the back of the RPS/EPS. There are two green LEDs for each RPS port:
Device Connected
Power Status
The following states provide status of an RPS/EPS port.
Fault Device
Connected
Power
Status
Message
Off Off Off Nothing Connected
On or Off Off On Not a valid state - should never happen
Off On Off Switch is connected, RPS is available but
not required
Off On On RPS is powering the connected device
Blinking Off Blinking RPS port is in fault mode
Off On Blinking Switch is requesting power, RPS can not
provide it
Blinking On Off Switch is unplugged, but RPS is powering
switch
Device Connected LED
Power Status LED
Device Connected
Power Status
R1 R2 R3 R4
RPS 1 RPS 2 RPS 3 RPS 4
RPS Power: 12V backup to one connected device. Lowest-numbered port has priority.
!
ProCurve 600 RPS/EPS
(J8168A)