3-30 Service Manual
4085-001
Terminology:
• TP refers to the PerfectFinish tank presence sensor.
• TF refers to the PerfectFinish fluid level sensor state.
Once this screen is displayed, the sensor can be manually actuated.
When the sensor is closed, C is displayed. When the sensor is open,
O is displayed. If the wrong message is displayed, the sensor is
malfunctioning.
TP=O = Tank Missing
TP=C = Tank Present
TF=O = Cartridge Full
TF=C = Not Full
To exit the test, select Return or Stop.
Miscellaneous Sensors
This test is used to determine if a group of miscellaneous sensors is
working correctly. To run the test, select Misc Sensors from the
BASE SENSOR TESTS menu. The following screen is displayed:
Terminology:
• CS refers to the cam stepper home sensor state.
Once this screen is displayed, the sensor can be manually actuated.
When the sensor is closed, C is displayed. When the sensor is open,
O is displayed. If the wrong message is displayed, the sensor is
malfunctioning.
To exit the test, select Return or Stop.
Motors Sensors
CS=O