V. e - CLEANING THE INTERIOR:
For cleaning both stainless steel and anodized alumi-
num interiors, the use of baking soda as described in
section V. d” is recommended. Use on breaker strips
as well as door gaskets. All interior fittings are remov-
able without tools to facilitate cleaning.
VI. a - ADJUSTING THE SHELVES:
For shelves mounted on pins, first select the desired
location and remove the white plastic covers in the
interior back and sides by rotating them counter-clock-
wise. Remove the shelf pins by rotating them counter-
clockwise. Install the pins in the desired location by
rotating clockwise. Make sure the pin is securely tight-
ened down. Do not over tighten. Slide the shelf into
its new position, and replace the white plastic covers
into the holes vacated by the shelf pins.
-5-
VI. MISC. OPERATIONS
V. CARE & MAINTENANCE (contd)
V. d - CLEANING THE EXTERIOR:
Exterior stainless steel should be cleaned with warm
water, mild soap and a soft cloth. Apply with a damp-
ened cloth and wipe in the direction of the metal grain.
Avoid the use of strong detergents and gritty, abra-
sive cleaners as they may tend to mar and scratch the
surface. Do NOT use cleansers containing chlorine,
this may promote corrosion of the stainless steel.
Care should also be taken to avoid splashing the unit
with water, containing chlorinated cleansers, when
mopping the floor around the unit.
For stubborn odor spills, use baking soda and water
(mixed to a 1 TBSP baking soda to 1 pint water ratio).
VII. MICROPROCESSOR CONTROL
VIII. a - MICROPROCESSOR CONTROL FEATURES:
Internal Time Clock
Eliminates defrost time clock (refrigerator and freezer models only).
Will display only at Start Up.
Must be reset after a power failure.
See Setting The 24-Hour Clock on Page 10. (Also required at Start Up)
Will automatically update for Daylight Savings Time. See Setting Daylight Savings
Time on page 11.
Water Resistant Housing
The digital controller is water resistant not only from the face of the control, but also
from the rear of the housing.
Parameter/Service Levels
See Customer/Service Parameters on Page 7 - 8.
Defrost Lockouts - See Setting Defrost Lockouts on page 13
Customers can set up to 4 different defrost lockout periods. The lockout prevents the
unit from going into a defrost cycle during peak kitchen use. Note: The 24-hour clock
must be set for this feature to operate correctly.
Your new Traulsen R or A Series Convertible Refrigerator or Freezer is equipped
with an electronic microprocessor control, which precisely regulates opera-
tion. It is supplied from the factory completely ready for use. See pages 5 thru
14 for more information.
°F °C
FREEZER
SET