Specifications
The following tables list specifications for the GEN Interface Modules:
1000BASE-SX (3CB9LG2MC) Module Cabling Requirements
1000BASE-LX (3CB9LG2SC) Module Cabling Requirements
Due to the dual media (single-mode and multimode) support of the
1000BASE-LX module, an offset-launch mode-conditioning patch cord
assembly is required to meet the specifications for multimode (MMF)
operation. This patch cord is not required for single mode (SMF)
operation. Patch cords come in various lengths and can be ordered
from Siecor Operations (800-743-2675, fax: 828-327-5973). The
following table lists the part number information:
Fiber Type
Modal Bandwidth
(MHz•km)
Segment Length
62.5/125 microns MMF 160 Up to 220 m (722 ft)
62.5/125 microns MMF 200 Up to 275 m (902 ft)
50/125 microns MMF 400 Up to 500 m (1,640 ft)
50/125 microns MMF 500 Up to 550 m (1,804 ft)
10/125 microns SMF Not applicable Not supported
Fiber Type
Modal Bandwidth
(MHz•km) Segment Length
62.5/125 microns MMF 500 Up to 550 m (1,804 ft)
50/125 microns MMF 400 Up to 550 m (1,804 ft)
50/125 microns MMF 500 Up to 550 m (1,804 ft)
10/125 microns SMF Not applicable Up to 5 km (16,404 ft)
Patch Cord Cable
Assembly Part Number
Description
39575802KMCXXXM* Mode-conditioning patch cord for 62.5 micron cables
39575802CMCXXXM* Mode-conditioning patch cord for 50 micron cables
* XXX = the length of the cable in meters.