3Com 3C16895 7-slot Chassis Switch User Manual


 
Upgrading Software 59
The file you selected is SW7750-V300R-.app, are you sure? Yes or
No(Y/N) y
On reboot,SW7750-V300R-.app will become the default application file
to boot!
7 Type Y to run the primary image:
Do you want to run snec400.app now? Yes or No(Y/N)? Y
No Backup Image If you do not enter the number of a backup boot file, the
following text displays:
Please input the backup boot file number :
Input Error!
Failed to select backup image file!
Type Y to run the primary boot file:
Do you want to run snec400.app now? Yes or No(Y/N)? Y
Backup Image Fails If the backup image fails and another backup image
configuration does not exist, the Switch 7750 will try to find any valid image on
the flash. This image is not the primary or backup image:
All Images Fail If all images fail, the Switch 7750 will return to the boot menu:
primary image : snec400.app
backup image : SW7750-V300R-.app
There is one passed image in addition:
File Number File Size(bytes) File Name
========================================================
1. 6256229 SW7750-V300RE-8016.app
Press Ctrl+B to enter Boot Menu... 0
Auto-booting....................
Auto booting file is snec400.app
No LPU application file < vxworks.app > in flash
Please download LPU application file vxworks.app to flash
No correct main file to boot!
loading backup image file to boot!
Auto booting backup file is SW7750-V300R-.app