22 CHAPTER 2: INSTALLING THE SWITCH
You must use the screws supplied with the mounting brackets. Damage
caused to the unit by using incorrect screws invalidates your warranty.
4 Repeat steps 2 and 3 for the other side of the Switch.
5 Insert the Switch into the 19-inch rack and secure with suitable screws
(not provided). Ensure that ventilation holes are not obstructed.
6 Connect network cabling.
7 Finally place a unit information label on the unit in an easily accessible
position. The unit information label shows the following:
The 3Com product name of the Switch
The 3Com 3C number of the Switch
The unique MAC address (Ethernet address) of the Switch
The serial number of the Switch
You may need this information for fault reporting purposes.
Placing Units On
TopofEachOther
If the Switch units are free-standing, up to eight units can be placed one
on top of the other. If you are mixing a variety of SuperStack
®
3Switch
and Hub units, the smaller units must be positioned at the top.
If you are placing Switch units one on top of the other, you must use the
self-adhesive rubber pads supplied. Apply the pads to the underside of
each Switch, sticking one in the marked area at each corner. Place the
Switch units on top of each other, ensuring that the pads of the upper
unit line up with the recesses of the lower unit.
Stacking Units Switch 4400 units can be stacked together and then treated as a single
manageable unit with one IP address. Any combination of 24-port and
48-port units is allowed in a single stack, as long as the total number of
front panel ports does not exceed the limit of 192 ports. The following
combinations are allowed:
4 x 48-port Switches
3 x 48-port Switches and 2 x 24-port Switches
2 x 48-port Switches and 4 x 24-port Switches
1 x 48-port Switch and 6 x 24-port Switches
8 x 24-port Switches