3Com PSE2500-A3 Power Supply User Manual


 
User Manual
PSE2500-A3 External PoE
Power System
Chapter 4
Installation and
Debugging
4-4
Figure 4-1 Physical installation
4.3 Installing Rectifiers
Standalone rectifier is installed by sliding into the power bracket,
pushing until the rectifier is fully inserted, and closing the handle on
the rectifier.
1) Verify that the AC circuit breakers in the distribution module
are in the “OFF” position
2) Place the module in the bracket and slide it toward the
backplane until it contacts the backplane
3) Close the handle on the front of the rectifier and verify that
the rectifier is firmly seated.
See Figure4-2 for the rectifier installation.