3M MN55144-1000 Tablet Accessory User Manual


 
17
Operation (Continued)
Figure 3-2—Controls, Valves and Switches
The case sealer has a circuit breaker located in
the electrical enclosure on the left side of the
machine frame. If circuit becomes overloaded
and circuit
breaker trips, unplug the machine
electrical
cord and determine cause of overload.
After two minutes, plug machine electrical cord
into outlet and restart machine by rotating the
On/Off switch to Off (O) then On (I).
Main Air On/Off Valve/Pressure Regulator/
Filter (Figure 3-3)
This set of pneumatic components controls,
regulates and filters plant air supply to the two
separate control circuits of the case sealer.
On/Off Valve (Figure 3-2)
On—turn arrows on switch toward the front of the
machine; Off—turn arrows on switch toward the
left side of the machine.
Note: Turning air supply off automatically bleeds
air pressure from the case sealer air circuits.
Electrical On/Off Switch (Figure 3-2)
The box drive belts are turned on and off with the
electrical switch on the side of the machine
frame.
Always turn off the air when machine is not in
use, when servicing the machine, or when
connecting or disconnecting air supply line.
Note: The air valve has provisions for lockout/
tagout according to plant regulations.
Figure 3-3—On/Off Valve/Regulator/Filter