Configuring Interface Connections
16-5
16
Web – Click Port, Port Configuration or Trunk Configuration. Modify the required
interface settings, and click Apply.
Figure 16-2 Port - Port Configuration
CLI – Select the interface, and then enter the required settings.
Console(config)#interface ethernet 1/13 45-1
Console(config-if)#description RD SW#13 45-2
Console(config-if)#shutdown 45-6
.
Console(config-if)#no shutdown
Console(config-if)#no negotiation 45-3
Console(config-if)#speed-duplex 100half 45-2
.
Console(config-if)#negotiation
Console(config-if)#capabilities 100half 45-4
Console(config-if)#capabilities 100full
Console(config-if)#capabilities flowcontrol
Console(config-if)#exit
Console(config)#interface ethernet 1/21
Console(config-if)#media-type copper-forced 45-6
Console(config-if)#