Acer EM250 Laptop User Manual


 
Chapter 5 147
Clearing Password Check and BIOS Recovery
This section provide you the standard operating procedures of clearing password and BIOS recovery for
eMachines eM250. eMachines eM250 provides one Hardware Open Gap on main board for clearing password
check, and one Hotkey for enabling BIOS Recovery.
Clearing Password Check
Hardware Open Gap Description
Steps for Clearing BIOS Password Check
If users set BIOS Password (Supervisor Password and/or User Password) for a security reason, BIOS will ask
the password during systems POST or when systems enter to BIOS Setup menu. However, once it is
necessary to bypass the password check, users need to short the HW Gap to clear the password by the
following steps:
Power Off the system, and remove HDD, AC and Battery from the machine.
Open the back cover of the machine, and locate the HW Gap on M/B as shown above.
Use an electric conductivity tool to short the two points of the HW Gap.
Plug in AC power, keep the short condition on the HW Gap, and press Power Button to power on
the system till BIOS POST finish. Then remove the tool from the HW Gap.
Restart system. Press F2 key to enter BIOS Setup menu.
If there is no Password request, BIOS Password is cleared. Otherwise, please follow the steps and
try again.
NOTE: The steps are only for clearing BIOS Password (Supervisor Password and User Password).
Item Description Location
R219 Clear CMOS Jumper 3G bay, near the 3G
connector