Acer X1260K Projector User Manual


 
X1160 Series/X1260 Series/X1160Z Series/X1260K Refresh Condential
4-6
- Ref. below table
Note: The defect criteria follows TI specication.
6. Focus test
Procedure - Test equipment: video generator.
- Test signal: analog 1024 x 768@60Hz
- Test Pattern: full screen or MEME Sony
Inspection item - Focus check
Criteria - From screen 1.5 M via visual to check the focus,
look at the entire screen, focus shall be clear,
crisp, and sharp over the entire surface of the
display pattern. (Blur word on one of the corner
after adjustment is acceptable. However, the
word should at least be recognizable.)
7. Color performance
Procedure - Test equipment: video generator.
- Test signal: DVI (HDMI) 720p,1080i
- Test Pattern: Master, In focus II or SMPTE RP-
133
* Please refer to 4-2 to enter service mode.
Use 720P & 1080i signal, master pattern to do
HDTV test. Color cannot discolor to purple and
blue. If the test result is discoloration or icker-
ing, please return the unit back to repair cent-
ers.
Inspection item - Check if each color level is well-functioned.
- color saturations
Criteria - Screen appears normal. It should not have any
abnormal condition, such as lines appear on the
screen and so on.
- Color appears normal.
- It is acceptable to have few lines ashing at the
center and on the edge of 1080i image. How-
ever, rest of the image should appears stable.
- RGBW should all appear normal on the screen
and sort from R -G-B-W.
- Color levels should be sufcient and normal.
InFocus II
/ 64 gray RGBW
Master
SMPTE RP-133
MEME Sony
Full screen