Addonics Technologies AD5EHPMEU3 Computer Drive User Manual


 
www.addonics.com Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/
RAID 3 (Stripe set with dedicated parity)
Number of drives: at least 3
Unit capacity: size of one member times number of members minus one.
Spares: yes
Fault tolerance: can withstand the loss of one drive without losing data.
RAID 3 works by striping data for individual I/O blocks across all members
except one, which contains parity data for the stripe set computed internally by
the Port Multiplier. In the event of failure, the missing information can be
calculated using the parity information.
RAID 5 (Stripe set with striped parity)
Number of drives: at least 3
Unit capacity: size of one member times number of members minus one.
Spares: yes
Fault tolerance: can withstand the loss of one drive without losing data.
RAID 5 works by striping entire I/O blocks across all members of the set, with
each member taking turns carrying parity data computed by the Port Multiplier.
In the event of failure, the missing information can be calculated using the
parity information.
CLONE (Mirror set)
Number of drives: at least 2
Unit capacity: size of one member.
Spares: yes
Fault tolerance: can withstand the loss of any number of drives without losing
data as long as at least one complete member remains online. CLONE mode
works the same way as RAID 1, by maintaining a complete copy of the entire
set of data on each drive.
LARGE (Spanned set)
Number of drives: at least 2
Unit capacity: 100% of all drives together regardless of differences in size
Spares: no
Fault tolerance: cannot withstand the loss of any drives without losing data.
However, some data may be recovered as long as the drive(s) carrying the file
system data (boot record, directory, etc.) remain online. LARGE mode is
neither a RAID nor is it a JBOD. It works by declaring the sum of all available
space of the member drives as a single unit, without striping the data. As each
member is filled, new data is stored on the next.
Notes about Spare Drives
If EZ mode is disabled (SW1:2 ON), all individual drives not configured as array
members will be offered to the host adapter as separate units.
To create an array with one or more spares, set or modify the RAID mode while
the spares are disconnected from the Port Multiplier. When EZ mode is
enabled (SW1:2 OFF), individual drives connected when an array is present
are considered spare. Spare drives must be equal to or larger in size than the
smallest member. When any type of array is defined, individual units will be
considered spare.